Amprobe ACD-45PQ Power-Quality-Clamp Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Amprobe ACD-45PQ Power-Quality-Clamp herunter. Amprobe ACD-45PQ Power-Quality-Clamp User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - ACD-45PQ

Users Manual• Mode d’emploi• Bedienungshandbuch• Manual d’Uso• Manual de usoACD-45PQ 600A Power Quality Clamp

Seite 2

4AutoVATM Function Set the slide-switch function-selector to the position.• With no input, the meter displays “ ” when it is ready.• With no ACA

Seite 3

5Peak-rms ModePeak-rms compares and displays the maximum RMS value of surge voltage or current with durations as short as 65ms. When ACV or ACA fu

Seite 4

6In ACA function, activating the Hz function during significant measurements can get the most appropriate trigger level to avoid electrical noises in m

Seite 5

7power factor, is no longer the only component constituting the overall power factor. Harmonics do increase apparent power and thus decrease the overa

Seite 6 - CONTENTS

8Single-Phase Power & 3-Phase Balanced-Load Power FunctionsSet the slide-switch function-selector to the “3~Bal • 1~” Power position.• Default at

Seite 7 - Safety Information

9Note:1. Under proper measurement setups for load circuits, the W (real power) readings are always positive. Negative W readings indicate reversed cla

Seite 8

10Set the slide-switch function-selector to the “3~Bal • 1~” Power position. Setup power measurements as mentioned in the previous “Single-Phase Power

Seite 9 - CAUTION

11• After the kWHr Recording session is stopped (“ ”) properly, the new result will supersede the previous one stored in the non-volatile memory. You

Seite 10 - Function

123-Phase 4-Wire (3 4W) Unbalanced-Load Power Function• Set the slide-switch function-selector to the “3~Un-Bal” Power position. Press “3W•4W” button

Seite 11 - Peak-rms Mode

13• Then clamp the jaws around “Line 3” as reminded by annunciators “ L3”, and connect Black test probe (COM terminal) to “Line n (neutral)” and Red

Seite 13

14/ FunctionsSet the slide-switch function-selector to the / function position. Default at last selected function. Press SELECT button to toggle

Seite 14

15Auto Power Off Quick TestPress-and-hold the 3W.4W button while powering the meter on. The LCD displays “” & “ ” to confirm activation right after

Seite 15

16SPECIFICATIONSGeneral SpecicationsDisplay : Voltage functions: 6000 counts LCD display Power Ohm & Hz functions: 9999 counts LCD display ACA c

Seite 16

17E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, E

Seite 17

18True RMS ACV & ACA clamp-on accuracies are specified from 0% to 100% of range or otherwise specified. Maximum Crest Factor are as specified below,

Seite 18

19ACA Current (Clamp-on)Range Accuracy 1) 2)50Hz / 60Hz40.00A, 400.0A, 600A 1.0% + 5d45Hz ~500Hz40.00A, 400.0A 2.0% + 5d600A 2.5% + 5d500Hz ~ 3.1kHz 4

Seite 19

20OhmsRange Accuracy5Hz ~ 500Hz 0.5%+4dOpen Circuit Voltage: 0.4VDC typicalAudible Continuity TesterAudible threshold: between 10 and 300.Response t

Seite 20 - Auto Power Off (APO)

212. Add 4d to specified accuracy for 3-Phase Balanced-Load Power measurements. 3. Add 1% to specified accuracy @ ACA fundamental < 6A or ACV fundame

Seite 21 - Line Frequency Setup

22MAINTENACE AND REPAIRWARNING To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input jacks and turn

Seite 22 - General Specications

23Battery ReplacementThe meter uses standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2 Loosen the 2 captive screws from the battery cover case.

Seite 23 - Electrical Specications

ACD-45PQ 600A Power Quality ClampUsers ManualMay 2010, Rev.1©2010 Amprobe Test Tools.All rights reserved. Printed in TaiwanEnglish

Seite 25

Limited Warranty and Limitation of LiabilityYour Amprobe product will be free from defects in material and workmanship for 1 year from the date of pur

Seite 26 - Audible Continuity Tester

ACD-45PQ 600A Power Quality Clamp1 Transformer Clamp Jaws for AC current magnetic field pick up2 Jaw marking lines for ACA (& thus Power) position

Seite 27 - 3-Phase Unbalanced-Load Power

ACD-45PQ 600A Power Quality ClampCONTENTSSYMBOLS ...

Seite 28 - Cleaning and Storage

1SYMBOLSCaution! Risk of electric shockCaution! Refer to the explanation in this ManualDouble Insulation or Reinforced insulationAlternating Curre

Seite 29 - Battery Replacement

2Measurement Category III (CAT III) is for measurements performed in the building installation. Examples are measurements on distribution boards, circ

Seite 30

3UNPACKING AND INSPECTIONYour shipping carton should include:1 ACD-45PQ 600A Power Quality Clamp1 Test Leads (Black x 1; Red x 1)1 Bag1 Users Manu

Kommentare zu diesen Handbüchern

Keine Kommentare

Panasonic KXTG6021 manuales

Manuales del propietario y guías del usuario para Contestadores automáticos Panasonic KXTG6021.
Ofrecemos 1 manuales en pdf Panasonic KXTG6021 para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Contestadores automáticos Panasonic

Modelos Tipo de documento
KXTCD735 Manual de usuario    Panasonic KXTCD735 User manual, 114 paginas
KXTCD725 Manual de usuario    Panasonic KXTCD725 User manual, 100 paginas
KXTVP100E Manual de usuario   Panasonic KXTVP100E User manual, 57 paginas
KXTCD210E Manual de usuario   Panasonic KXTCD210E User manual, 68 paginas
KXTVP50E Manual de usuario   Panasonic KXTVP50E User manual, 16 paginas
KXTG8421E Manual de usuario   Panasonic KXTG8421E User manual, 60 paginas
KXTG5431 Manual de usuario   Panasonic KXTG5431 User manual, 76 paginas
KXTCD580 Manual de usuario   Panasonic KXTCD560 User manual, 68 paginas
KXPRX120E Manual de usuario   Panasonic KXPRX120E User manual, 68 paginas
KXTG6073 Manual de usuario   Panasonic KXTG6073 User manual, 56 paginas
KXTG5623 Manual de usuario   Panasonic KXTG5623 User manual [en] , 56 paginas
KXTG5438 Manual de usuario   Panasonic KXTG5438 User manual, 72 paginas
KXTCD820E Manual de usuario   Panasonic KXTCD820E User manual, 76 paginas
KXTS730S Manual de usuario   Panasonic KXTS730S User manual, 6 paginas
KXTS730S Manual de usuario   Panasonic KXTS730S User manual, 6 paginas
KXTG6432 Manual de usuario   Panasonic KXTG6432 User manual, 64 paginas
KXTG6522 Manual de usuario   Panasonic KXTG6522 User manual, 64 paginas
KXTCD290E Manual de usuario   Panasonic KXTCD290E User manual, 72 paginas
KXTD612E Manual de usuario   Panasonic KXTD612E User manual, 221 paginas
KXTG1032 Manual de usuario   Panasonic KXTG1032 User manual, 52 paginas