0908
For detailed specifications go to www.Amprobe.eu
Industrial Clamp Multimeters
B TRMS Measurement
B AC/DC Voltage up to 1000V, AC/DC
Current up to 1000A, Resistance,
Capacitance, Temperature, and
Continuity Buzzer
B Dynamic Min/Max/Avg recording
B In-rush Peak Current
capture (1 ms response)
B Temperature measurement
B Dual Display of ºC & ºF readings
B Continuity Buzzer
B Reading Hold function
B Auto/Manual Ranging and
Auto Power Off
B Analog Bar Graph indicator
B Jaw opening 52 mm
B Safety acc. EN 61010, CAT III/600 V
FEATURES ACDC-620T ACDC-3000 ACD-330T
Current AC/DC
400.0, 1000A 40.00, 400.0, 1000A 400.0, 1000A
AC + DC TRMS Voltage
N/A 4.000, 40.00, 400.0, 750V N/A
AC + DC TRMS Current
N/A 40.00, 400.0, 1000A N/A
Resistance
400.0 Ω, 4.000 kΩ 400.0k Ω, 4.000MΩ, 40.00MΩ 400.0 Ω, 4.000 kΩ
Capacitance
400.0, 4000 µF N/A N/A
Frequency
N/A
10.00-199.99 Hz, 1999 Hz,
2.00-19.99 kHz, 199.9 kHz 100, 1000 Hz
Temperature
-40°C to 1372°C N/A N/A
% Duty Cycle
N/A 0.0-99.9% N/A
In-rush Peak Current
Max (Ac or DC)
400.0, 1000 A N/A N/A
Continuity Buzzer
Yes Yes Yes
Diode Test
Yes Yes N/A
ACDC-3000 Digital 1000A AC/DC Clamp Multimeter
B TRMS Measurement
B AC Voltage up to 750V, DC Voltage up
to 1000V, AC/DC Current up to 1000A,
Resistance, Frequency, % Duty Cycle,
Continuity Buzzer
B Dynamic Recording of Max, Min and
Average readings
B In-rush Peak Current capture (1 ms response)
B Dual Display of Amp & Freq.,
Amps & Duty Cycle, Voltage & Freq.,
Voltage & Duty Cycle
B 43 Segment, High speed, Analog
Bar Graph
B Continuity Buzzer
B Auto/Manual Ranging and
Auto Power Off
B Jaw opening 52 mm
B Safety acc. EN 61010, CAT III/600 V
ACD-330T Digital AC Clamp Multimeter
B TRMS Measurement
B AC/DC Voltage up to 1000V, AC Current up to
1000A, Resistance, Continuity Buzzer, Frequency
B Dynamic Min/Max/Avg Recording
B In-rush Peak Current capture (1 ms)
B Reading Hold function
B Dual Display of Frequency with Current or Voltage
B Continuity Buzzer and Diode Test
B Auto/Manual ranging
B Auto power off
B Jaw opening 52 mm
B Safety acc. EN 61010, CAT III/600 V
AC Voltage
400.0, 1000V 4.000, 40.00, 400.0, 750V 400.0, 1000V
DC Voltage
400.0, 1000V 4.000, 40.00, 400.0, 1000V 400.0, 1000V
For detailed specifications go to www.Amprobe.eu
Power Quality Clamp Meter
ACD-56 HPQ Power Quality Digital Clamp Multimeters
B TRMS & Backlight Screen
B AC Current up to 400A
B AC/DC Voltage up to 600V
B Resistance
B Frequency
B Capacitance
B Voltage and Current Harmonics up to 25th
with THD%
B Non-contact Voltage Level Detection
B Audible continuity
B Auto and manual ranging
B Auto-check feature automatically
selects DCV, ACV or Resistance Ω
B MAX/MIN/AVG recording
B Auto power off
B “Third hand” - test probe holder
B Jaw opening 30 mm
B Safety acc. EN 61010, CAT III/600 V
These instruments combine the standard features of professional clamp meters, with full Power
analyzing capabilities. Increase measuring efficiency using the ACD-31P or ACD-41PQ with an
optional PC interface kit (RS-232 KIT2). View individual harmonics using the ACD-56 HPQ.
B TRMS Measurement and Backlight Screen
B Measures Total Harmonics
Distortion (41PQ only)
B Voltage to 600V, Current to 1000A
B Resistance, Frequency & Temperature
B Active (W), Reactive (var) and
Apparent (VA) Power with
Power Factor
B Auto VA - Auto Selection of AC Volts,
DC Volts or AC Amps (ACD-41PQ only)
B Optional PC interface capability
B Audible continuity
B Peak hold and Data hold
B “Third hand” - test probe holder
B Voltage overload protection for
all functions up to 600V AC/DC
B Jaw opening 45 mm
B Safety acc. EN 61010, CAT III/600V
ACD-31P, ACD-41PQ
1000A Power Quality Clamp Meters
FEATURES ACD-31P ACD-41PQ ACD-56 HPQ
TRMS Measurement
Yes Yes
AC Current
40.00 / 400.0 / 1000 A 0 - 399.9 A
Voltage AC/DC
600.0 V 1.6 - 599.9 V
Resistance
999.9 Ohms 0 – 499.9 / 999/ 1999 Ohms
Frequency
5.00Hz to 500.0 Hz 40.0 - 399.9 Hz
Active Power (W)
0 to 600.0 kW N/A
Reactive Power (VAR)
0 to 600.0 kVAR N/A
Apparent Power (VA)
0 to 600.0 kVA N/A
Power Factor
0.10 to 0.99 0.20 - 1.00
THD-R
N/A 0.0% to 99.9% N/A
THD-F
N/A 0.0% to 99.9% N/A
Temperature
-50° C to 300° C N/A
AC Peak Voltage
N/A 10 to 850 V @ 1ms Rt
AC Peak Current
N/A 10 to 800 A @ 1ms Rt
Voltage / Current
Harmonics
N/A THD, Individual harmonics 1 to 25
CLAMP METERS
ACDC-620T Digital 1000A AC/DC Clamp Multimeter
Kommentare zu diesen Handbüchern