USER'S
MANUAL
AM-100
AM-105 TRMS
AM-110 TRMS
Digital
Multimeters
Seitenansicht 0
1 2 3 4 5 6 ... 14 15

Inhaltsverzeichnis

Seite 1 - USER'S

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS Digital Multimeters

Seite 2

9 HOLD The hold feature freezes the display for later view. Press the HOLD button momentarily to activate or to exit the hold feature. MAX The max

Seite 3

10 Battery and Fuse replacement Battery use: Standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2 Protection-reinforced CE Version fuses: Fuse

Seite 4

11 6) Specifications General Specifications Display : 3-3/4 digits 4000 counts LCD display Polarity : Automatic Update Rate : 3 per second nominal

Seite 5

12 Sleep Mode Timing: Idle for 30 minutes Sleep Mode Consumption: 300µA typical for AM100; 360µA typical for AM-105 TRMS & AM-110 TRMS Dimension:

Seite 6

13 DC Current RANGE Accuracy Burden Voltage 400.0µA 2.0% + 5d 0.15mV/µA 4000µA 1.2% + 3d 0.15mV/µA 40.00mA 2.0% + 5d 3.3mV/mA 400.0mA 1.2% + 3d 3

Seite 7

LIMITED WARRANTY Congratulations! Your new instrument has been quality crafted according to quality standards and contains quality components and wo

Seite 8

1 1) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in

Seite 9

2 WARNING To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. To avoid electrical shock hazard, observe th

Seite 10

3 3) PRODUCT DESCRIPTION This user's manual uses only representative model for illustrations. Please refer specification details for function av

Seite 11

4 4) OPERATION DC Voltage, AC Voltage, & Hz Frequency functions Note: 1) AC 400.0mV range selection is by RANGE button manually, and is spe

Seite 12

5 Ω Resistance, and Continuity functions Defaults at Ω. Press SELECT button momentarily to select Continuity function which is convenient for check

Seite 13

6 Diode test, Capacitance functions Defaults at Ω. Press SELECT button momentarily 2 times to select Diode test function. Normal forward voltage d

Seite 14

7 µA, mA, and A Current functions Default at DC. Press SELECT button momentarily to select AC. CAUTION When measuring a 3-phase system, special att

Seite 15

8 Relative zero mode Relative zero mode allows the user to offset the meter consecutive measurements with the displaying reading as the reference