Seite 1 - Users Manual

AM-60 Compact DMM withNCV & Logic TestUsers Manual• Mode d’emploi• Bedienungshandbuch• Manual d’Uso• Manual de uso

Seite 2

5Resistance and CapacitanceNote – To improve the measurement accuracy of small value capacitor, record the reading with the test leads open then subst

Seite 3 - NCV & Logic Test

6Display HoldManual Ranging and Auto RangingAuto Power Off (Battery Saver)

Seite 4

7Disable Auto Power OffNon-Contact Voltage (Volt sense)1. Volt sense switch will be activated on any function or at OFF status.2. Test leads are not u

Seite 5

8SPECIFICATIONSGeneral SpecicationsDisplay : 2000 counts.Polarity Indication : Automatic, positive implied, negative indicated.Overrange Indic

Seite 6 - CONTENTS

9DC / AC VoltsRange AC Accuracy200.0mV * Unspecified 2.000V * ±(1.5%+5dgt) 50Hz ~ 300Hz20.00V ~ 200.0V *±(1.5%+5dgt) 50Hz ~ 500Hz 750V AC / 100

Seite 7

10* AC Conversion Type : Conversion type and additional specification are same as DC/AC Voltage.** Ampere Testing Duty Ratio TableAmpere Testing Time

Seite 8 - //A//Hz position

11FrequencyRange Sensitivity Accuracy2000Hz ~ 200.0KHz>1.5 Vac rms,<5 Vac rmsFrequency :0.01%±1digit2.000MHz ~ 20.00MHz>2 Vac rms,<5 Vac r

Seite 9 - OPERATION

12MAINTENACEIf there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the ca

Seite 10 - Measuring DC / AC Current

13Fuse ReplacementRefer to the following figure to replace fuse :CAUTION: • Use only a fuse with the amperage, interrupt, voltage, and speed rating sp

Seite 14

AM-60Compact DMM withNCV & Logic TestUsers Manual©2009 Amprobe Test Tools.All rights reserved. Printed in ChinaEnglish

Seite 15 - Diode Check and Continuity

Limited Warranty and Limitation of LiabilityYour Amprobe product will be free from defects in material and workmanship for 1 year from the date of pu

Seite 16 -  - EMC: EN61326-1

AM-60 Compact DMM with NCV & Logic Test1235641233-3/4 digits 2000 counts LCD displayPush-buttons for special functions & featuresSelector to t

Seite 17 - TROUBLE SHOOTING

1AM-60 Compact DMM with NCV & Logic TestCONTENTSSYMBOLS ...

Seite 18 - Battery Replacement

2SYMBOLSWarning! Dangerous Voltage (Risk of electric shock).Caution ! Refer to the user’s manual before using this Meter.Double Insulation or Reinf

Seite 19

3• Do not apply more than the rated voltage, as marked on Meter, between terminals or between any terminal and earth ground.• Do not attempt a curre

Seite 20

4INTRODUCTIONMultimeter AM-60 can be used to measure voltage, resistance, capacitance, frequency, current; It is an electronic measuring instrument th